The OFS 2000-W model is equipped with Automatic Gain Control (AGC) to compensate for variations in opacity caused by particulate matter or moisture carried in the stack flow.
The OFS uses EPA Method 14 optical scintillation technology with Digital Signal Processing (DSP) electronics to provide highly accurate, path-averaged air velocity measurements for Continuous Emissions Monitoring Systems (CEMS). OFS accuracy has been proven by US National Institute of Standards (NIST) and at installations worldwide.
- Full cross-stack/duct measurement for superior accuracy
- Unaffected by distance & pressure, moisture or opacity
- Non-intrusive; nothing inflow path
- No flow media high-temperature limits
- No calibration necessary
- Built-in continuous self-test diagnostics
- Easy installation and alignment
- No moving parts: operates unattended – 24/7/365
- Rugged ultra-low maintenance design for harsh environments
Measurement technique: Optical scintillation
Velocity range: 0.1m to 40m/s velocity
Path length: 0.2 to 12m
Accuracy: 2% of reading
Resolution: 0.1m/s
Response time: (User selectable) three sec to 600 sec
Long term drift: <1% >per year
Media temperature: No upper limit (for temp < 150°F an activator heater may be required)
Light source: 670nm red LED
Power requirements: 100-240 VAC, 50/60Hz (Transmitter 12VA, Control Enclosure 40VA)
Data output: 4-20mA and/or RS-232 ASCII serial I/O
Operating temperature range: -40° to 140°F (-40° to 60°C)
Humidity: 0 to 100%, Condensing
Dust intrusion: IP65
Mounting flange: 9in Dia. ANSI (150# 4in bolt pattern )